From: Robert Openshaw <openshaw@erich.triumf.ca>
Date: Tue, 13 Jul 1999 17:36:13 -0700
To: E614Chambers@relay.phys.ualberta.ca
Subject: Ageing test PH profiles
Attached files are pulse height profiles of recent DME ageing tests:
E2PRF.PS - AWM2100V mass flowmeter in flow path
E3E4PRF.PS - E3 - "Pure" DME (i.e. no additional materials in flow path)
E4 - R311 activated copper O2 filter in flow
path
E5E6PRF.PS - E5 - 2 ton epoxy, conductive epoxy, plastic connector, 1
part RTV all in 2 copper containers in series in flow
path
E6 - initially just an empty copper container in
flow path,
later (after 0.081 C/cm-wire) put 2 part
RTV in container
E7E8PRF.PS - E7 -2 ton epoxy in copper container in flow path
E8 - plastic cable connector in copper container
in flow path
E9E10PRF.PS - E9 - conductive epoxy in copper container in flow path
E10 - 1 part RTV in copper container in flow
path
E11E12PR.PS - E11 - "Silguard" RTV in copper container in flow path
E12 - Urethane rubber in copper container in
flow path
NOTE: in addition to above chamber specific materials ALL chambers were
fed from a common gas system containing various regulators, valves,
rotameters, tubing, etc. Thus all the DME gas was exposed to stainless
steel, copper, zinc, brass, aluminum, chrome, polyethylene, natural
rubber, viton, buna-N, neoprene, teflon, and glass prior to entering
the test chambers.
Filename: E11e12pr.ps
Filename: E2prf.ps
Filename: E3e4prf.ps
Filename: E5e6prf.ps
Filename: E7e8prf.ps
Filename: E9e10prf.ps
Ageing test PH profiles / Robert Openshaw
- Created for the The Center for Subatomic Research E614 Project Projects Page.
- Created by The CoCoBoard.