Attached files are pulse height profiles of recent DME ageing tests: E2PRF.PS - AWM2100V mass flowmeter in flow path E3E4PRF.PS - E3 - "Pure" DME (i.e. no additional materials in flow path) E4 - R311 activated copper O2 filter in flow path E5E6PRF.PS - E5 - 2 ton epoxy, conductive epoxy, plastic connector, 1 part RTV all in 2 copper containers in series in flow path E6 - initially just an empty copper container in flow path, later (after 0.081 C/cm-wire) put 2 part RTV in container E7E8PRF.PS - E7 -2 ton epoxy in copper container in flow path E8 - plastic cable connector in copper container in flow path E9E10PRF.PS - E9 - conductive epoxy in copper container in flow path E10 - 1 part RTV in copper container in flow path E11E12PR.PS - E11 - "Silguard" RTV in copper container in flow path E12 - Urethane rubber in copper container in flow path NOTE: in addition to above chamber specific materials ALL chambers were fed from a common gas system containing various regulators, valves, rotameters, tubing, etc. Thus all the DME gas was exposed to stainless steel, copper, zinc, brass, aluminum, chrome, polyethylene, natural rubber, viton, buna-N, neoprene, teflon, and glass prior to entering the test chambers.