From: Blair Jamieson <jamieson@physics.ubc.ca>
Date: Mon, 9 Jul 2001 18:45:15 -0700 (PDT)
To: <E614software@relay.phys.ualberta.ca>
Subject: More Plane and Wire Systematic Studies


Hi all,

The attached files are slides showing work in progress on the effect on
the fit michel spectrum of various plane shifts.

The files are:
	  1.no_shift.ps (54 KB) "",
	     Comparing MC values to fit values of spectrum for no
               wire chamber hits.  Bottom plots are difference (MC-Fit).
          2. p_us_dense_shift100.ps (57 KB) "",
             Comparing fit with no shift to fit with shift of all up
               stream dense stack planes by 100 micrometers.  Bottom plots
               are difference ( no shift fit - shifted fit ).
          3. p_ds_dense_shift100.ps (56 KB) "",
          4. p_22_23_rot15m.ps (57 KB) "",
             Comparing to rotation by 15 mrad of planes 22 and 23.
          5. p_21_22_23_24_rot15m.ps (58 KB) ""
          6. p_ds_dense_rot15m.ps (57 KB) "",
          7. p_us_dense_rot15m.ps (58 KB) ""
-Blair

\\//   Blair Jamieson  (jamieson@physics.ubc.ca)                    \\/\//
//\\   University of British Columbia      TRIUMF                   //\/\\
\\//   (604) 822-3714                      (604) 222-1047 ext. 6441 \\/\//
//\\   6224 Agricultural Road              4004 Wesbrook Mall       //\/\\
\\//   Vancouver, BC  V6T 1Z1              Vancouver, BC  V6T 2A3   \\/\//


Filename: no_shift.ps

Filename: p_us_dense_shift100.ps

Filename: p_ds_dense_shift100.ps

Filename: p_22_23_rot15m.ps

Filename: p_21_22_23_24_rot15m.ps

Filename: p_ds_dense_rot15m.ps

Filename: p_us_dense_rot15m.ps


More Plane and Wire Systematic Studies / Blair Jamieson

Created for the The Center for Subatomic Research E614 Project Projects Page.
Created by The CoCoBoard.