Nominal settings as of November 2002: _________ BEAMLINE: Beamline settings can be calculated using an OpenOffice spreadsheet. In the e614 account, you can run OpenOffice by typing ~/OpenOffice1.0/soffice & The spreadsheet file is here: /home/e614/spreadsheets/new_dacs.sxc It is recommended that you save this as "work.sxc" before making changes. You can predict the tune for a desired momentum by changing the number in bold. Note that all DAC settings can be found by looking at the .snap files (which are just text files). DO NOT DISCONNECT OR DEPOWER THE M13B1 #1 NMR PROBE, due to a problem with radiation damage; we may not recover the B1 NMR signal at all if that happens! There is a second magnetometer in the counting room for B1NMR ranges 2 and 3. You'll have to: turn off the readout module (between the NMR modules), switch the data readout cable in the back of the magnetometers from one to the other so the slow controls can read it, and turn the readout module back on... There are actually three ways to tell what a magnet is set to: the DAC (an integer telling the power supply what to do), and two current readbacks (labelled "readback" and "DCT"). (You can usually ignore the "setpoint", as long as it's "close".) If you can't get the DAC, readback, and DCT to agree simultaneously with the values listed here, then: - If the DCT and readback agree, set according to the DCT. - If the DCT and readback disagree, one of them is probably wrong, so set according to the DAC. For the dipole magnets (B1 and B2), trust the NMR above all else. In any case, if there was disagreement with anything please state this in the elog. PLEASE POST A SNAPSHOT OF THE UBEAM WINDOW TO ELOG after setting the tune. ===SETTINGS FOR 29.6 MeV/c SURFACE MUONS: M13 Absorber position: 0 Gas Degrader setting: 5% CO2 (95% He) (Wait 90 minutes for the degrader to flush.) Filmstrip Degrader setting: 1 (open hole) Magnet settings file: m13dev_29p6_all.snap F0 jaws: 9 mm F0 slits: 41 mm F1 slits: 10 mm F2 Slits: 20 mm DAC/DCT/NMR values (as of 12:40, 23 November 2002) B1: 2594/40A/870.4G B2: 2972/44A/950.2G (NMR range 1) Q1: 635/151.1A Q2: 7744/58.8A (57.6A?) Q3: 635/110.1A Q4: 770/92.1A Q5: 723/127.0A Q6: 546/64.5A Q7: 488/57.2A (58.7A?) Trigger: M ===SETTINGS FOR 32.8 MeV/c: M13 Absorber position: 0 Gas Degrader setting: 5% CO2 (95% He) Filmstrip Degrader setting: 9 (20 thou) Magnet settings file: m13beam_32p8_all.snap F0 jaws: 8 mm F0 slits: 41 mm F1 slits: 10 mm F2 slits: 20 mm DAC/DCT/NMR values (as of 31 October 2002): B1NMR: 2877/44A/964.5G B2NMR: 3302/49A/1052.9G (NMR range 1) Q1: 704/168.1A Q2: 8581/63.9A Q3: 704/122.9A Q4: 853/102.0A Q5: 801/140.9A Q6: 605/71.9A Q7: 541/64.9A Trigger: M ===SETTINGS FOR 50 MeV/c (SPRAY): M13 Absorber position: 0 Gas Degrader setting: 5% CO2 (95% He) (but does it matter?) Magnet settings file: m13beam_50_spray.snap F0 jaws: 18 mm F0 slits: 80 mm F1 slits: 10 mm F2 slits: 20 mm NMR values within a few percent of these should be fine for spray tunes... DAC/DCT/NMR values (as of 17:40 on 26 October 2002): B1NMR: 4420/68A/1470.3G B2NMR: 4995/75A/1605.0G (NMR range 2) All quads off except Q1 and Q2. Q1: 417/99.34A Q2: 13750/102.49A Trigger: DS ===SETTINGS FOR 120 MeV/c PIONS (SPRAY): M13 Absorber position: 1 Magnet settings files (load all of these): m13dev_120_all_slits.snap m13beam_120_all_spray.snap F0 jaws: 9 mm F0 slits: 41 mm F1 slits: 10 mm F2 Slits: 20 mm NMR values within a few percent of these should be fine for spray tunes... DAC/DCT/NMR values (as of 4:30pm 26 October 2002): B1NMR: 10642/163A/3528.7G B2NMR: 11920/180A/3852.1G (NMR range 3) All quads off except Q1 and Q2. Q1: 1000/238.10A Q2: 33000/246.34A(?) Gas Degrader setting: Doesn't matter. Trigger: DS, or MLT. (Usually some runs with each.) ===SETTINGS FOR 1AT1 TARGET SCANS: TURN ALL HV OFF!!! (Do this before any other changes here, or the chambers could be damaged!) M13 Absorber position: 0 (empty hole) Filmstrip degrader position: 1 (empty hole) Magnet settings: same as for 29.6 MeV/c. Slit settings: F0 jaws: 150 mm F0 slits: 150 mm F1 slits: 120 mm (won't open to 150) F2 slits: 150 mm Gas degrader setting: doesn't matter. Trigger: None (no data). ________________ HV & THRESHOLDS: DC's: HV: 1950 V Threshold: -150 mV Outer PC's: HV: 2050 V Threshold: Ganged wires: -300 mV Central wires: -250 mV Target PC's: HV: 2050 V Threshold: -150 mV Groups used in efficiency scans: DC Planes in Group A: 1,2,5,6,9,10,13,14,17,18,21,22,25,26,29,30,33,34,37,38,41,42 DC Planes in Group B: 3,4,7,8,11,12,15,16,19,20,23,24,27,28,31,32,35,36,39,40,43,44 PC Planes in Group A: 1,2,5,6,9,10 PC Planes in Group B: 3,4,7,8,11,12