From Grant, elog http://midtwist.triumf.ca:8081/EL/021025.4746?exp=twist The following is a list of the voltage and current readouts from the front panels of the fastbus crate power supplies. These should be considered nominal values for the current population of the crates. Any variation of these values by a few percent should not be considered problematic. I will keep an eye on these values to see what typical variation we might expect. FB Crate #1 V_Supply (V) V_Readout (V) I_Readout (A) ============ ============= ============= +15 +14.98 000 -15 -14.94 000 +5 +5.09 095 -5.2 -5.18 150 -2 -2.03 042 FB Crate #2 V_Supply (V) V_Readout (V) I_Readout (A) ============ ============= ============= +15 +15.12 001 -15 -15.01 001 +5 +5.05 096 -5.2 -5.22 144 -2 -2.01 041