Generating STRs for MOFIA

Procedure:
   The method used for generating the STRs used by MOFIA has been altered from that used in the past.

    The GARFIELD output for GEANT (which is a drift time table) is now read in by MOFIA. This means that you CANNOT read in the old STR files that MOFIA used to read in (which were tables of angle,time,distance) . Now, in MOFIA the STRs, at the desired angles, are calculated during intialization time. The module: strs_mod contains the code used for this process. The call to create the STRs resides in the calibrations_mod, in the routine ReadSTR. Please refer to the module strs_mod for further information on this process.

Comments on the new method used.

Last Updated: July 10, 2001 by Roy Wilds