The current "standard" set of GEANT runs, called mcmass-6, can be found under /home/e614/geantlinks. The data were produced using GEANT version "mcmass-6" (the name of the CVS tag), this ffcards settings, and the official blackbox spectra.
The current "standard" analysis of these geant data is mcmass6-1 under /home/e614/mofialinks. MOFIA CVS version is hftest-20030730 (the one affected by the Pi bug!). In choosing analysis settings the approach was to use MOFIA defaults: the "old" classification and the wire center helix fit. This is the kcm file (a variation of the "fall2002" one).
range | spectrum type | black box spectrum and parset |
---|---|---|
8000-8999 | base | spectrum 8, parset 2. |
9000-9999 | base | spectrum 9, parset 2 |
1000-1099 | rho | spectrum 12 |
2000-2099 | eta | spectrum 13 |
3000-3099 | xi | spectrum 10, parset 2 |
4000-4099 | delta | spectrum 11, parset 2 |
5000-5099 | xixidelta | spectrum 14 |
6000-6099 | xidelta | spectrum 15 |